This is the mail archive of the ecos-patches@sourceware.org mailing list for the eCos project.


Index Nav: [Date Index] [Subject Index] [Author Index] [Thread Index]
Message Nav: [Date Prev] [Date Next] [Thread Prev] [Thread Next]
Other format: [Raw text]

[Bug 1001629] bsd stack uses wrong timeout values if hz != 100


Please do not reply to this email, use the link below.

http://bugs.ecos.sourceware.org/show_bug.cgi?id=1001629

--- Comment #3 from Grant Edwards <grant.b.edwards@gmail.com> ---

I'd like to commit this patch.

I independently discovered this problem when the IPv6 stack was
prematurely timing out interface address assignments that had
non-infinite lifetimes.  I traced the problem to the exact same spot
and arrived at a nearly identical solution before I found this
bug/patch in Bugzilla.

I've tested the patch with both 10ms and 1ms system ticks, and I'm
satisfied that it's good (it's going into my production code).

Comments?

-- 