Re: running test cases
On Mon, Apr 06, 2009 at 01:55:02AM -0700, grahamlab wrote:
>
> At last some success!!
> I can download a file using hyperterm.
> I cannot do this in minicom, I think it may have to do with flow control.
> How do I set flow control in the Linux environment?
Using minicom:
^A-o
Serial port setup
...
Or prepare
cat >~/.minicom.redboot <<EOF
pu port /dev/ttyS0
pu baudrate 38400
pu bits 8
pu parity N
pu stopbits 1
pu rtscts No
EOF
and then run minicom as 'minicom -o redboot'
To check the settings
$ stty -a -F /dev/ttyS0 ;# man stty, man minicom.
Sergei
> Graham
>
> Sergei Gavrikov-4 wrote:
> >
> > grahamlab wrote:
> >>
> >> I follow Sergei's instructions and get the minicom upload screen - but
> >> then
> >> nothing happens.
> >> When I try from Hyperterm it says "no response from remote system"
> >>
> >> Graham
> >
> > I just wonder, Do you enter `load' command in RedBoot before to start
> > the upload?
> >
> > Redboot> load -r -b %{freememlo} -m ymodem
> > C
> >
> > At once, as you hit <Enter> you have to see 'C' letter and then you must
> > start upload ('send file' in HT). Again, what's about flow control?
> > Valid settings are 38400,n,8,1 (no software/hardware flow control).
> >
> >
> > Sergei
> >
> > --
> > Before posting, please read the FAQ: http://ecos.sourceware.org/fom/ecos
> > and search the list archive: http://ecos.sourceware.org/ml/ecos-discuss
> >
> >
> >
>
> --
> View this message in context: http://www.nabble.com/running-test-cases-tp22873616p22904693.html
> Sent from the Sourceware - ecos-discuss mailing list archive at Nabble.com.
>
>
> --
> Before posting, please read the FAQ: http://ecos.sourceware.org/fom/ecos
> and search the list archive: http://ecos.sourceware.org/ml/ecos-discuss
--
Before posting, please read the FAQ: http://ecos.sourceware.org/fom/ecos
and search the list archive: http://ecos.sourceware.org/ml/ecos-discuss