Re: ADC polling vs. ADC generated interrupt
- From: Uwe Kindler <uwe_kindler at web dot de>
- To: ecos-discuss at sourceware dot org
- Cc: Peter Last NameHuszar <duci750 at yahoo dot com>
- Date: Sun, 28 Dec 2008 11:13:30 +0100
- Subject: Re: [ECOS] ADC polling vs. ADC generated interrupt
Hello Peter,
the current implementation of the ADC driver for the LPC24xx is
efficient because it requires only one single interrupt to service up to
8 ADC channels at the same time. All active channels will be read in one
single ISR. The interrupt frequency is as high as the configured sample
rate. That means if you only need 10 samples per second per channel then
the timer ISR will be serviced 10 times per second.
Another advantage of the current implementation is, that it is possible
to use the eCos ADC driver and application specific ADC polling at the
same time. That means you could use the buffered eCos ADC driver for the
first 4 ADC channels and you could poll the remaining 4 channels without
using the eCos ADC driver.
The current implementation would not work for LPC22xx varaints because
they do not have per channel A/D data registers. For LPC22xx and LPC21xx
variants you need a solution that raises an interrupt for each single
A/D conversion and then you would read the A/D value from the ADDR
register. You would need a timer channel to generate the correct
sampling frequency and you would need the ADC interrupts to read the
data from the ADDR register.
Because of these differences I think it would be better to create a
separate ADC driver for former LPC2xxx variants.
Regards, Uwe
--