Hi all,
I'm writing a driver for a radio module and I want to set with
configtool some static configuration parameters that I don't need to
change at run-time. I had a look as usual at the serial driver to see
how it implements options (e.g. baudrate) and then I wrote my own code
that I report below:
cdl_option WIS_RADIO_DEFAULT_PHYRATE {
display "PHY data rate"
flavor data
legal_values { "53_3" 80 "106_7" 160 200 320 400 480 }
default_value {"53_3"}
description "
PHY data rate."
}
cdl_option WIS_RADIO_DEFAULT_TXPWR {
display "TX power level"
flavor data
legal_values 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
default_value 0
description "
TX power level."
}
cdl_option WIS_RADIO_DEFAULT_TFC {
display "Time Frequency code"
flavor data
legal_values 1 2 3 4 5 6 7
default_value 1
description "
Time Frequency code."
}
The problem is that when I start configtool and I try to change the
value of one parameter with the pull-down option menu I get the message
"There's one unresolved conflict, make the change anyway?" and if I
change it in the conflict window I get a illegal value conflict. I
tried the same thing changing the baud rate in the serial driver and I
get the same message so maybe the problem is not in my code. Any
suggestions? Thanks.
Michele