[Bug 1001440] New: can_lpc2xxx.c: driver confuses 'bus error' and'bus off' conditions
- From: bugzilla-daemon at bugs dot ecos dot sourceware dot org
- To: ecos-bugs at ecos dot sourceware dot org
- Date: Tue, 3 Jan 2012 13:34:15 +0000
- Subject: [Bug 1001440] New: can_lpc2xxx.c: driver confuses 'bus error' and'bus off' conditions
- Auto-submitted: auto-generated
Please do not reply to this email. Use the web interface provided at:
http://bugs.ecos.sourceware.org/show_bug.cgi?id=1001440
Summary: can_lpc2xxx.c: driver confuses 'bus error' and 'bus
off' conditions
Product: eCos
Version: CVS
Platform: Other (please specify)
OS/Version: Cortex-M
Status: UNCONFIRMED
Severity: normal
Priority: low
Component: CAN
AssignedTo: unassigned@bugs.ecos.sourceware.org
ReportedBy: bernard.fouche@kuantic.com
CC: ecos-bugs@ecos.sourceware.org
Class: Advice Request
In function lpc2xxx_can_get_even():
//
// 1: Bus Error Interrupt -- this bit is set if the BEIE bit in CANIE
is 1, and the CAN
// controller detects an error on the bus.
//
if (event & ICR_BUS_ERR)
{
pevent->flags |= CYGNUM_CAN_EVENT_BUS_OFF;
LPC2XXX_DBG_PRINT("ICR_BUS_ERR (%p)\n", (void*) chan);
}
The comment is okay but the resulting code is incorrect: 'bus off' means the
controller is disconnected from the bus because it had many problems sending
data. The LPC2XXX/17XX controller reports 'bus off' condition in bit 'BS' of
register CANxGSR: the tested bit comes from CANxICR and just signals an error
on the bus, not that the controller is disconnected.
This function should raise CYGNUM_CAN_EVENT_PHY_FAULT and supplementary
processing is needed for 'bus off'.
--