--- Comment #8 from Christophe Coutand <ecos@hotmail.co.uk> 2011-08-07 05:16:32 BST ---
In the plf_intr.h of the soclib package, you can overwrite the clock definition
provided from the hal_intr.h.
You must select the correct interrupt for the RTC clock:
#define CYGNUM_HAL_INTERRUPT_RTC YOUR_SOCLIB_TIMER_IRQ_NUM
and define the 3 macos used by eCos to access the clock:
externC CYG_WORD32 cyg_hal_clock_period;
#define CYGHWR_HAL_CLOCK_PERIOD_DEFINED
#define HAL_CLOCK_INITIALIZE( _period_ ) \
CYG_MACRO_START \
/* Place code here * /
cyg_hal_clock_period = _period_; \
CYG_MACRO_END
#define HAL_CLOCK_RESET( _vector_, _period_ ) \
/* Place code here * /
CYG_MACRO_END
#define HAL_CLOCK_READ( _pvalue_ ) \
CYG_MACRO_START \
/* Place code here * /
CYG_MACRO_END
#define CYGHWR_HAL_CLOCK_CONTROL_DEFINED
--